Report About Prostate Cancer: PET in Radiotherapy Planning

Do you need this or any other assignment done for you from scratch?
We have qualified writers to help you.
We assure you a quality paper that is 100% free from plagiarism and AI.
You can choose either format of your choice ( Apa, Mla, Havard, Chicago, or any other)

NB: We do not resell your papers. Upon ordering, we do an original paper exclusively for you.

NB: All your data is kept safe from the public.

Click Here To Order Now!

Introduction:

[bookmark: _Hlk3485638]Imaging modality plays a great role in treatment planning. Positron emission tomography PET has been used in treatment planning in the delineation of Gross target volume GTV which is considered as the most important component in treatment planning. Also, PET Accuracy in the delineation of GTV impact on dose delivery to tumor tissue while delivering a low dose rate to healthy tissue or critical structure surrounding the tumor. PET has great sensitivity and specificity in the delineation of Gross target volume more than other imaging modality that has been used in treatment planning. because PET uses FDG and these an advantage that reduces the uncertainty in defining tumor margin in radiotherapy treatment planning. [1]

PET-based treatment planning:

Recently PET imaging or molecular imaging has been used in treatment planning for cancer patients. By using PET radiotracer 18F-FDG which allow viewing the molecular pathways for the target (tumor), metabolism, proliferation, oxygen delivery, and consumption many receptors or gene expression. Using PET images in treatment planning can give us information about tumor response to radiotherapy, can localize the reoccurring tumors in an early stage. The most important function of PET imaging in treatment planning is Delineation of tumor or target and organ at risk OAR. [9] Positron emission tomography PET, has an advantage in cancer patient management by using 18F-FDG as a tracer helps in the delineation of the target volume in non-small cell lung cancer NSCLC patients, head and neck squamous cell carcinoma HNSCC, and rectal carcinomas.[9] There is another PET radiotracers differ in their sensitivity and specificity which impact the image and the treatment planning. FDG it has non-specific uptake in tumor and high uptake in other areas such as infection or inflammation sites.[9][10] hypoxia imaging with PET a useful tool to know tumor response during radiotherapy treatment or identify the resistant tumor cells, and to deliver the higher radiation dose to the parts that radio-resistant which have a higher chance of tumor reoccurrence. [4] the best PET tracer should have these properties high uptake values in the tumor, high sensitivity and specificity in tumor site, low production cost, and availability.[5]

Why PET used in treatment planning:

  • Provide molecular information about the tumor.
  • Higher sensitivity, specificity, and accuracy due to PET tracers.
  • Provides accurate information about tumor stage.
  • Give information about tumor response and resistant to radiotherapy.
  • Accurate delineation of GTV.
  • Dose painting with hypoxia tracers (FMISO, FAZA, CU-ATSM) and FLT.
  • dose painting by numbers DPBN, shape the dose depending on the voxel intensity.
  • Accurate diagnosis of NSCLC and high contrast images.
  • Enhance the main aim of radiotherapy treatment by concentrated the radiation dose to the target and lower dose for surrounding tissue or OAR. [5][12][7]

PET Tracers (agents):

· FDG

The first use of PET-FDG was with non-small cancer lung cells NSCLC by accurate delineation for nodal and distant metastases. FDG-PET has been used with CT images due to the poor spatial resolution of FDG-PET.[9] FDG-PET more accurate than CT in localizing mediastinal nodal in SCLC, also FDG-PET helps to reduce the isolated nodal failures outside the clinical target volume CTV.[9] The resolution limits for PET 5-7mm, any object lower than this limit will have a weak signal which affects the resulting image.[9] Due to this limitation, there is the uncertainty of estimating the real tumor size. PET images may contain a signal noise. [12] FDG used as a guide through the segmentation process, then these segments combined to form the large target region. The main objective of segmentation to determine which part of the target will receive the primary dose and which one will have the higher dose GTV.[10] PET-avid delivery of a nonhomogeneous dose of FDG-PET to the target region, by concerted the higher dose to the avid region and lower dose to the OAR or keep the dose below the threshold of deterministic effects.[10] the disadvantage of FDG is non-specific uptakes values for tumor due to the high activity of glucose. [5]

· 18F-FDG PET/CT:

[bookmark: _Hlk3558885][bookmark: _Hlk3558888]Using FDG-PET with CT handle the limitation of low spatial resolution of PET. [9] Fusing PET images with CT images improve the accuracy of delineation, and high sensitivity, and specificity (96.6%) of tumor detection and contributed in treatment decision based on the changing of GTV. [11] since CT provides electron density data that improve the dose calculation in treatment planning. [12] Using two imaging modalities enhance the detection of reoccurrence tumors especially colorectal cancers.[11] Fusing techniques: (1) Hybrid PET/CT fusing the images in the system by RTP and (2) Fusing PET and CT images separately and two registration methods: (1) rigid and (2) deformable. In PET/CT it is important that the immobilization device fits with PET/CT, immobilization device such as masks and shoulder in head and neck cancer easily fits with PET/CT. PET/CT has been used in gate acquisition of lung and thoracic and excellent bowel preparation of abdominopelvic malignancies. Both PET and CT have artifacts due to patient motion especially respiratory motion which lead to the wrong estimation of SUV and tumor size. Inaccurate SUV due to a mismatch between PET and CT because of the difference in time acquisition. PET has superior sensitivity and specificity over CT in lung cancer helps to improve the therapeutic ratio by increasing the dose in the target site and minimize the dose in OAR and normal tissue. There is two correction techniques of respiratory motion 4D PET/CT, DIBH PET/CT. [12]

The uptake process 18F-FDG PET/CT:

  1. Before the examination, the patient had to be fasting for at least 6 hours.
  2. Then injects the patient with FDG, the amount of FDG calculated by [w×4+20] MBq.
  3. Then after 60 min, the PET and CT images obtained. [9]

· 18F-FLT

18F-fluorothymidine FLT it is cellular proliferation, phosphorylated by thymidine kinase inactive cells and trapped in the cell but does not marker DNA.[9][10] FLT is excellent image for tumor volume changes due to radiotherapy. [13] FLT can give information about the tumor response during the treatment course. After 15 to 18 fractioned doses ( chances in GTV is detectable. The uptake values of FLT decrease due to the reduction of tumor cell density during the treatment and this is impacting on the FLT signal.[14]

The uptake process of FLT-PET/CT:

  1. The patient fast for at least 6 hours before the examination.
  2. Rest for 15 min before the injection of 300-400MBq of FLT.
  3. The images were obtained in 60 min after injection.[13]

Comparison between FLT and FDG PET tracers in treatment planning:

FLT

FDG

esophageal cancer

Has a low dose to the lung and cardiac

Higher dose to lung and cardiac

rectal cancer

The same GTV for both

brain tumors

Superior in defining the target in the brain

Has high uptake value in cortical

reactive lymph nodes

May have some uptake value in reactive lymph nodes which increases the difficulty to distinguish active tumors.

specificity

excellent

Good

accuracy for nodal staging

excellent

Good

Primary tumors

Lower sensitivity to detect primary tumors

higher sensitivity to detect primary tumors

[9][10]

· 11C-methionine

The sensitivity of 11C-methionine PET in brain tumor is higher than FDG-PET due to the high activity of glucose in normal brain tissue. This is making 11C-methionine the best PET tracer for brain tumor delineation. [5] 11C-methionine provides biological information about the tumor and the response to treatment. 11C-methionine helps in diagnosis identify the tumor activity with primary and recurrent gliomas patients.[15] tumor grading may be estimated incorrectly in brain tumor especially gliomas kind because it is formed of heterogeneous and microscopic areas of necrosis. so, the biopsy may represent a small part of the primary tumor and underestimate the tumor grading. 11C-methionine shows that are a useful biomarker in gliomas patients and has a higher sensitivity of detection and delineation of the tumor. In contrast with FDG-PET, 11C-methionine can detect tumors with (hypometabolism or is metabolism). 11C-methionine can be used as guidance during the biopsy process.[16] 11C-methionine shows a high uptake value in the pituitary gland and can distinguish between pituitary adenoma and other normal tissue in the brain. These increasing the reduction of GTV and the radiation dose to the normal tissue and the parotid glands, lacrimal glands and inner ears. The drawback of 11C-methionine it has a shorter half-life 20 min, also there is uptake values in other sites such as lacrimal glands, parotid glands, nasopharynx, bone marrow, and normal pituitary gland. [17]

The uptake process of 11C-methionine:

  1. Injection the patient with 11C-methionine 210MBq.
  2. After 20 min PET image obtained in 3D for 5min /bed position. [15]

· 11C-Choline

11C-Choline can distinguish between curable diseases from metastatic diseases. [18]11C-Choline has been used for prostate cancer and contributed to choosing the best treatment strategy. 11C-Choline helps to improve the therapeutic ratio by high-precision radiation to the target and minimum dose to the normal tissue. It is not recommended using 11C-Choline in early diagnosis or tumor staging. The advantage of using 11C-Choline with prostate cancer that detects the target that localizes beyond the prostate bed so unnecessary radiation dose for prostate bed will be avoided.[19] 11C-Choline has sensitivity and specificity of 85%and 88% inpatient prostate-specific antigen (PSA). The limitation of 11C-Choline is cannot detect small lesions or low activity lesions. [20] other limitation of 11C-Choline cannot distinguish between tumor and non-tumor tissue in the prostate. [21]

The uptake process of 11C-Choline:

1. The patient fast at least for 6 hours before 11C-Choline PET/CT scan.

2. Then patient drink diluted oral contras 300 mg.

3. A rectal filling negative contract agent 100-200mL.

4. Then injected the patient of 691 ±70MBq of 11C-Choline.

5. Then after 5 min, the PET/CT images were obtained.[22]

· 68Ga-PSMA-PET 21

68Ga-PSMA-PET has high sensitivity and specificity in diagnosing prostate cancer. [23]68Ga-PSMA-PET can diagnosis the reoccurrence primary prostate cancer PCA.[21] 68Ga-PSMA helps to eliminate 35.7% Lymph nodes LNs out of CTV which enhances the therapeutic ratio by minimizing the dose to LNs. [23]

The uptake process of 68Ga-PSMA-PET:

  1. Patient fasts for at least 4 hours before injection.
  2. Then injected the patient 172±34 MBq of 68Ga-PSMA.
  3. Then after one-hour PET scan performed. [21]

· 18F-fluciclovine PET/CT

18F-fluciclovine has been used in postprostatectomy to delineate the volume target (prostate bed) and the changes that may affect the OAR. 18F-fluciclovine a non-physiologic uptake in prostate bed, lymph nodes, or bone. [24]

The uptake process of 18F-fluciclovine:

  1. The patient must fast at least for 4 hours.
  2. Then the patient injected with (371.6±12.4 MBq) over 2 min.
  3. The acquisitions of the pelvis to diaphragm obtained at 5-15.5min and at 16-27.5min. [24]

· Hypoxia Tracers:

Hypoxia traces have a great role in treatment planning provides a lot of information by Identify the resistant cells in the tumor. The target/background activity is less than FDG-PET. [10] Hypoxia traces is a nitroimidazole compound. [25] hypoxia tracer it is common to use in solid tumors such as head and neck squamous cell carcinomas (HNSCC). [26]

  1. (18F-MISO) the first hypoxia PET tracer can increase the dose to hypoxic tumor up to 105Gy, can detect different tumor sites in one patient.[26]
  2. (18F-FAZA) has the same uptake values and biodistribution as 18F-MISO, but the lower concentration in the tumor, that mean lower sensitivity in detection hypoxic sites.[26]

The importance of hypoxia tracer:

  1. Prediction of failure of radiotherapy.
  2. Prediction of chemotherapy-resistant (ꜜproliferation ꜜdrugs concentration).[26]

PET tracer

Cancer type

Sensitivity-specificity

In GTV delineation

FDG-PET

· Nonsmall cancer lung cells NSCLC

80-90%

85-100%

· Head and neck

50-96%

88-100%

· Cervical carcinoma

75-91%

92-100%

· Esophageal

30-78%

86-98%

· Prostate cancer

67%

83%

11C-Choline PET

· Prostate cancer

80%

96%

11C-Acetate PET

· Prostate cancer

80%

29%

[25][27]

FDG-PET in brachytherapy:

FDG-PET images have been used in brachytherapy for the cervix cancer patient. FDG-PET give significant information in 3D of the tumor or disease spread. The advantage from use FDG-PET image in treatment planning of cervix cancer patient is to reduce the dose to bladder and rectum due to the accurate dose coverage to the target volume. [28]

New PET tracer 18Ffluoroethyl-L-tyrosine FET:

The new PET tracer FET has used in the detection of glioma and has excellent sensitivity and specificity improving the detection. also, have been used with Highly malignant or high-grade glioma. FET-PET used with MRI-based plans to shows the contrast. A mismatch between FET-PET and MRI-based in target volume contour, which improve treatment planning. Also, FET-FDG shows other sites that CT-based did not cover.[29] FET-PET id better than FDG-PET in the detection of a brain tumor but have the same performance in grade glioma. FET-PET mean, and maximum target/background ratio only can distinguish between tumor tissues and nontumor tissues. FET-PET helps to identify the tumor response to radiotherapy and delineation of target volume before radiotherapy which helps in estimating the effect of radiotherapy and chemotherapy in the tumor.[30]

Nonsmall cancer lung cells NSCLC:

In intensity modulated radiotherapy IMRT PET and CT scan improve the treatment planning for NSCLC patients. [31] 18F-FDG PET/CT has the ability to distinguish between tumor tissues and healthy tissues with 93% sensitivity and 88% specificity. the sensitivity, accuracy, and positive predictive value in the detection of primary lung tumors are 94%,94%, and 100% respectively. 18F-FDG PET/CT contributed to changing the treatment planning during the treatment course.[32]

Bibliography:

  1. Salahuddin Ahmad, PET-based GTV definition is the future of radiotherapy treatment planning, Med. Phys. 39 (10), October 2012, [http://dx.doi.org10.1118/1.3694666].
  2. Vincent Grégoire, PET-Based Treatment Planning in Radiotherapy: A New Standard? , THE JOURNAL OF NUCLEAR MEDICINE • Vol. 48 • No. 1 (Suppl) • January 2007, J Nucl Med 2007; 48:68S–77S.
  3. Christina K. Speirs, PET-Based Radiation Therapy Planning, PET Clin 10 (2015) 27–44, http://dx.doi.org/10.1016/j.cpet.2014.09.003.
  4. Alexander Chi, The utility of positron emission tomography in the treatment planning of image-guided radiotherapy for non-small cell lung cancer, October 2014 | Volume 4 | Article 273,doi: 10.3389/fonc.2014.00273.
  5. Michael MacManus, Use of PET and PET/CT for Radiation Therapy Planning: IAEA expert report 2006–2007, Radiotherapy and Oncology 91 (2009) 85–94, doi:10.1016/j.radonc.2008.11.008.
  6. Daniela Thorwarth, Physical radiotherapy treatment planning based on functional PET/CT data, Radiotherapy and Oncology 96 (2010) 317–324, doi:10.1016/j.radonc.2010.07.012.
  7. ALEKSANDAR GRGIC, FDG-PET–Based Radiotherapy Planning in Lung Cancer: Optimum Breathing Protocol and Patient Positioning—An Intraindividual Comparison, Int. J. Radiation Oncology Biol. Phys., Vol. 73, No. 1, pp. 103–111, 2009 ,doi:10.1016/j.ijrobp.2008.03.063.
  8. Homer A. Macapinlac, Clinical Applications of Positron Emission Tomography/Computed Tomography Treatment Planning, Nucl Med 38:137-140 © 2008 Elsevier Inc. doi:10.1053/j.semnuclmed.2007.11.005.
  9. Judith van Loon,18FDG-PET-based radiation planning of mediastinal lymph nodes in limited disease small-cell lung cancer changes radiotherapy fields: A planning study, Radiotherapy and Oncology 87 (2008) 49–54, doi:10.1016/j.radonc.2008.02.019.
  10. Junzo Chino, Positron Emission Tomography in Radiation Treatment Planning The Potential of Metabolic Imaging, Radiol Clin N Am 51 (2013) 913–925, http://dx.doi.org/10.1016/j.rcl.2013.05.007.
  11. Vera Artiko, Can 18F-FDG PET/CT scan change treatment planning and be prognostic in recurrent colorectal carcinoma? A prospective and follow-up study, Hell J Nucl Med 2015; 18(1): 35-41.
  12. Paola G. Scripts, Technical Aspects of Positron Emission Tomography/Computed Tomography in Radiotherapy Treatment Planning, Nucl Med 42:283-288 © 2012 Elsevier Inc. http://dx.doi.org/10.1053/j.semnuclmed.2012.04.006.
  13. Guifang Zhang, Gradient-based delineation of the primary GTV on FLT PET in squamous cell cancer of the thoracic esophagus and impact on radiotherapy planning,Zhang et al. Radiation Oncology (2015) 10:11, DOI 10.1186/s13014-014-0304-5.
  14. Esther G.C. Troost ,18F-FLT PET/CT for Early Response Monitoring and Dose Escalation in Oropharyngeal Tumors, J Nucl Med 2010; 51:866–874, DOI: 10.2967/jnumed.109.069310.
  15. Matteo Santoni,[11C]-Methionine Positron Emission Tomography in the Postoperative Imaging and Followup of Patients with Primary and Recurrent Gliomas, Volume 2014, Article ID 463152, 6 pages, http://dx.doi.org/10.1155/2014/463152.
  16. S. Ceyssens, K. Van Laere,[11C]Methionine PET, Histopathology, and Survival in Primary Brain Tumors and Recurrence, Ceyssens AJNR 27 Aug 2006 www.ajnr.org.
  17. Taku N, Koulouri O, Scoffings D, Gurnell M, Burnet N. The use of 11carbon methionine positron emission tomography (PET) imaging to enhance radiotherapy planning in the treatment of a giant, invasive pituitary adenoma. BJR Case Rep 201; 2: 20160098.
  18. Francesco Ceci, Evaluation of Prostate Cancer with 11C-Choline PET/CT for Treatment Planning, Response Assessment, and Prognosis, J Nucl Med 2016; 57:49S–54S, DOI: 10.2967/jnumed.115.170126.
  19. Barbara Alicja Jereczek-Fossa,[11C]Choline PET/CT Impacts Treatment Decision Making in Patients With Prostate Cancer Referred for Radiotherapy, June 2014Volume 12, Issue 3, Pages 155–159, https://doi.org/10.1016/j.clgc.2013.11.002.
  20. Gregor Habl, 68Ga-PSMA-PET for radiation treatment planning in prostate cancer recurrences after surgery: Individualized medicine or new standard in salvage treatment, wileyonlinelibrary.com/journal/pros The Prostate. 2017;77:920–927, DOI 10.1002/pros.23347.
  21. Constantinos Zamboglou, MRI versus 68Ga-PSMA PET/CT for gross tumour volume delineation in the radiation treatment planning of primary prostate cancer, Eur J Nucl Med Mol Imaging (2016) 43:889–897, DOI 10.1007/s00259-015-3257-5.
  22. Michael Souvatzoglou ,Influence of 11C-choline PET/CT on the treatment planning for salvage radiation therapy in patients with biochemical recurrence of prostate cancer, Radiotherapy and Oncology 99 (2011) 193–200, doi:10.1016/j.radonc.2011.05.005.
  23. K. Schiller, Impact of 68Ga-PSMA-PET imaging on target volume definition and guidelines in radiation oncology – patterns of failure analysis in patients with primary diagnosis of prostate cancer, Schiller et al. Radiation Oncology (2018) 13:36 https://doi.org/10.1186/s13014-018-0977-2.
  24. Ashesh B. Jani, Impact of 18F-Fluciclovine PET on Target Volume Definition for Postprostatectomy Salvage Radiotherapy: Initial Findings from a Randomized Trial, J Nucl Med 2017; 58:412–418, DOI: 10.2967/jnumed.116.176057.
  25. Anca-Ligia Grosu, Positron Emission Tomography for Radiation Treatment Planning, Strahlenther Onkol 2005;181:483–99, DOI 10.1007/s00066-005-1422-7.
  26. Marina Hodoli, Hypoxia PET Tracers in EBRT Dose Planning in Head and Neck Cancer, Current Radiopharmaceuticals, 2015, 8, 32-37.
  27. Ilaria Grassi, the clinical use of PET with 11C-acetate, Am J Nucl Med Mol Imaging 2012;2(1):33-47, ISSN:2160-8407/ajnmmi1106004.
  28. LILIE L. LIN, M.D, ADAPTIVE BRACHYTHERAPY TREATMENT PLANNING FOR CERVICAL CANCER USING FDG-PET, Int. J. Radiation Oncology Biol. Phys., Vol. 67, No. 1, pp. 91–96, 2007, doi:10.1016/j.ijrobp.2006.08.017.
  29. Dasantha T Jaymanne, Utilizing 18F-fluoroethyl-L-tyrosine positron emission tomography in high-grade glioma for radiation treatment planning in patients with contraindications to MRI, Journal of Medical Imaging and Radiation Oncology 62 (2018) 122–127, doi:10.1111/1754-9485.12676.
  30. Vincent Dunet, Performance of 18F-FET versus 18F-FDG-PET for the diagnosis and grading of brain tumors: systematic review and meta-analysis, Neuro Oncol. 2016 Mar; 18(3): 426–434. Published online 2015 Aug4. DOI: 10.1093/neuonc/nov148.
  31. Davina Pawaroo, Non–Small Cell Lung Carcinoma: Accuracy of PET/CT in Determining the Size of T1 and T2 Primary Tumors, American Journal of Roentgenology. 2011;196: 1176-1181.10.2214/AJR.10.4980.
  32. Emine Budak, The Contribution of Fluorine 18F-FDG PET/CT to Lung Cancer Diagnosis, Staging and Treatment Planning, Mol Imaging Radionucl Ther 2018;27:73-80 DOI:10.4274/mirt.53315.
Do you need this or any other assignment done for you from scratch?
We have qualified writers to help you.
We assure you a quality paper that is 100% free from plagiarism and AI.
You can choose either format of your choice ( Apa, Mla, Havard, Chicago, or any other)

NB: We do not resell your papers. Upon ordering, we do an original paper exclusively for you.

NB: All your data is kept safe from the public.

Click Here To Order Now!